Cartis diligence evidence schedule
Scaleway DC5 PAR2 Data Center
PRJ-1190 · Site · Saint-Ouen-l-Aumone, Île-de-France, France
Record last updated Oct 28, 2026
Scope and capacity
Scaleway DC5, also designated PAR2, is an operating hyperscale data center northwest of Paris. The 16,000-square-meter facility contains 12 private suites and provides more than 20 MW of IT design capacity. Direct free cooling with adiabatic support produced a reported 2024 PUE of 1.16, and the site’s electricity is covered by renewable guarantees of origin.
Headline: More than 20 MW Planned critical IT
Numbers refer to their stated physical boundaries and are not added together. Source dates, claim dates and record updates have different meanings. Missing dates and locators are not inferred.
Claims and exhibit sources
Jump to a claim (4)
Reported capacity · More than 20 MW operating IT design capacity
Actual · Scaleway DC5 PAR2 Data Center (Project)
Claim 154760 · Recorded claim type: Actual · Review: Approved · Claim date: Oct 21, 2020
Headline treatment: Selected headline
- Scaleway Impact Report 2024
Scaleway · Document date: Jun 1, 2025 · Corroborating
Source reference: SRC-7470 · Fact sheet · Recorded authority: Party primary
Source URL
https://www-uploads.scaleway.com/Impact_Report2024_A4_EN_e63efcae20.pdf
https://www-uploads.scaleway.com/Impact_Report2024_A4_EN_e63efcae20.pdf
- Introducing DC5 PAR2
Scaleway · Document date: Oct 21, 2020 · Primary
Source reference: SRC-7469 · Company announcement · Recorded authority: Party primary
Source URL
https://www.scaleway.com/en/blog/introducing-dc5-hyper-scale-mechanical-cooling-datacenter/
https://www.scaleway.com/en/blog/introducing-dc5-hyper-scale-mechanical-cooling-datacenter/
Building area · 16,000 square meters
Actual · Scaleway DC5 PAR2 Data Center (Project)
Claim 154761 · Recorded claim type: Actual · Review: Approved · Claim date: Oct 21, 2020
- Scaleway Impact Report 2024
Scaleway · Document date: Jun 1, 2025 · Corroborating
Source reference: SRC-7470 · Fact sheet · Recorded authority: Party primary
Source URL
https://www-uploads.scaleway.com/Impact_Report2024_A4_EN_e63efcae20.pdf
https://www-uploads.scaleway.com/Impact_Report2024_A4_EN_e63efcae20.pdf
- Introducing DC5 PAR2
Scaleway · Document date: Oct 21, 2020 · Primary
Source reference: SRC-7469 · Company announcement · Recorded authority: Party primary
Source URL
https://www.scaleway.com/en/blog/introducing-dc5-hyper-scale-mechanical-cooling-datacenter/
https://www.scaleway.com/en/blog/introducing-dc5-hyper-scale-mechanical-cooling-datacenter/
Suite count · 12 suites
Actual · Scaleway DC5 PAR2 Data Center (Project)
Claim 154762 · Recorded claim type: Actual · Review: Approved · Claim date: Oct 21, 2020
- Scaleway Impact Report 2024
Scaleway · Document date: Jun 1, 2025 · Corroborating
Source reference: SRC-7470 · Fact sheet · Recorded authority: Party primary
Source URL
https://www-uploads.scaleway.com/Impact_Report2024_A4_EN_e63efcae20.pdf
https://www-uploads.scaleway.com/Impact_Report2024_A4_EN_e63efcae20.pdf
- Introducing DC5 PAR2
Scaleway · Document date: Oct 21, 2020 · Primary
Source reference: SRC-7469 · Company announcement · Recorded authority: Party primary
Source URL
https://www.scaleway.com/en/blog/introducing-dc5-hyper-scale-mechanical-cooling-datacenter/
https://www.scaleway.com/en/blog/introducing-dc5-hyper-scale-mechanical-cooling-datacenter/
PUE · 1.16 ratio
Actual · Scaleway DC5 PAR2 Data Center (Project)
Claim 154763 · Recorded claim type: Actual · Review: Approved · Claim date: Oct 21, 2020
- Scaleway Impact Report 2024
Scaleway · Document date: Jun 1, 2025 · Corroborating
Source reference: SRC-7470 · Fact sheet · Recorded authority: Party primary
Source URL
https://www-uploads.scaleway.com/Impact_Report2024_A4_EN_e63efcae20.pdf
https://www-uploads.scaleway.com/Impact_Report2024_A4_EN_e63efcae20.pdf
- Introducing DC5 PAR2
Scaleway · Document date: Oct 21, 2020 · Primary
Source reference: SRC-7469 · Company announcement · Recorded authority: Party primary
Source URL
https://www.scaleway.com/en/blog/introducing-dc5-hyper-scale-mechanical-cooling-datacenter/
https://www.scaleway.com/en/blog/introducing-dc5-hyper-scale-mechanical-cooling-datacenter/
Counterparties and capital
This schedule captures public Cartis research. It is not a title, lien or legal-opinion report. Document page/section locators and claim review timestamps are included only when published; this version has no separate locator or claim-review-time feed.